Development and Validation of a Green UV-spectroscopic Approach for Estimating Dutasteride in Tablet and Bulk forms of Administration with Greenness Evaluation by AGREE and MoGAPI

 

K. Vara Prasada Rao, Sridevi Ranjitha Karanam*, Y. Srinivasa Rao,

P. Rohan Ratnakar, J. Kumari

Department of Pharmaceutical Analysis, Vignan Institute of Pharmaceutical Technology (Autonomous), Visakhapatnam, Andhra Pradesh - 530049, India.

*Corresponding Author E-mail: ranjitha.karanam@gmail.com

 

ABSTRACT:

A simple, precise, and eco-friendly UV spectroscopic technique was created and approved for the quantitative measurement of dutasteride in tablet and bulk medication forms of administration. The method employs ethanol as the solvent, with maximum absorbance observed at 213nm. With a correlation coefficient (r2) of 0.999, linearity was confirmed over the concentration range of 10–60µg/mL, suggesting a good linear connection between absorbance and concentration. Sandell's sensitivity was 0.0625µg/cm˛, and the molar absorptivity (ε) was 6.63 × 10˛L/mol/cm. The concentration was calculated using the regression equation y = 0.016x + 0.0084. High accuracy with an average recovery of 99.2% and precision with intraday and interday %RSD values of 1.62% and 1.35%, respectively, were proven by method validation carried out in compliance with ICH Q2(R1) requirements. With LOD and LOQ values of 0.37µg/mL and 1.11 µg/mL, respectively, the technique showed good sensitivity. Greenness assessment, conducted using the Analytical GREEnness (AGREE) metric and MoGAPI, indicated strong compliance with eco-friendly principles, with maximum scores for avoidance of derivatization, minimal waste generation, elimination of toxic reagents, and integration of processes to reduce energy use. Moderate scores were observed for low energy consumption and operator safety, while relatively lower scores were noted for in-situ applicability and the use of renewable-source reagents. The new approach is appropriate for continuous quality monitoring of dutasteride in the drug formulations since it is accurate, economical, and environmentally friendly.

 

KEYWORDS: Dutasteride, UV-Spectroscopy, Method Validation, Green Analytical Chemistry, AGREE, MoGAPI, Bulk Drug, Tablet Dosage Forms.

 

 


INTRODUCTION: 

An antiandrogenic medication called dutasteride is mostly used to treat adult males with benign prostatic hyperplasia (BPH). It works by inhibiting type-1 5-alpha reductase and type 2 isoenzymes, which are responsible for converting testosterone into the powerful androgen dihydrotestosterone (DHT), which causes the growth of the prostate. By lowering intraprostatic and circulating DHT levels, this dual inhibition improves urine flow, shrinks the prostate, and eases the symptoms of BPH. Brand names like Avodart and Jalyn are used to sell dutasteride. Its molecular weight is 528.54g/mol, and its chemical formula is C₂₇H₃₀F₆N₂O₂. It dissolves in organic solvents like ethanol, DMF, and DMSO but is insoluble in water. It is more soluble in eucalyptus oil-oleic acid mixtures. It is classified as BCS Class II, meaning it has poor solubility but good permeability.1-6

 

Figure 1: Chemical structure of Dutasteride

Source: Chemical structure of Dutasteride, Chem3D Pro version 7.0.0 software 7

 

Pharmacodynamically, dutasteride reduces DHT in a dose-dependent manner, with over 90% reduction after one year of 0.5mg daily treatment. Pharmacokinetically, it is effectively absorbed, with a bioavailability of about 60% and peak plasma levels in two to three hours. It has a broad distribution volume (300-500L) and a high protein binding rate (~99%). Metabolism is predominantly mediated by CYP3A4 and CYP3A5, which produce hydroxylated metabolites. Excretion is primarily fecal, with a terminal half-life of around five weeks, indicating a long duration of activity. Adverse consequences include low libido, erectile dysfunction, decreased sperm volume, and breast tenderness. Serious concerns include allergic reactions and a slightly higher incidence of high-grade prostate cancer. Clinically, dutasteride is used to treat symptomatic BPH, avoid acute urine retention, and reduce the need for BPH-related surgery. It can be administered alone or with tamsulosin for increased efficacy.8-11

 

The examined literature focuses on several analytical techniques developed and validated for estimating Dutasteride in bulk medicines, pharmaceutical formulations, and biological materials.

 

Several investigations used RP-HPLC procedures, which were precise, robust, and dependable for Dutasteride analysis. Bansode et al. validated a technique for Dutasteride using Tamsulosin capsules, demonstrating high accuracy (98-102%) and precision (RSD<2%). For tablets, Patel et al. created an RP-HPLC approach with methanol-water mobile phase that is effective from 1 to 12μg/mL concentration. Deshmukh et al. devised another RP-HPLC method with a 10-minute run time that demonstrated selectivity, linearity, and robustness in accordance with ICH criteria.12,13

Spectrophotometric approaches were also presented. Ghosh et al. and Islam et al. developed simple UV spectrophotometric methods for Dutasteride in bulk and formulations, with λmax at 240-241nm. Both systems demonstrated high linearity, precision, and recovery, making them ideal for routine quality control. The same category of medications was also reported.Srinivasarao et al. created a first-order derivative spectrophotometric approach for measuring both Solifenacin Succinate and Tamsulosin Hydrochloride in mixed dosage forms. The approach uses zero-crossing sites (265nm for Solifenacin, 250nm for Tamsulosin) and shows good linearity, sensitivity, precision, and accuracy for routine analysis14,15.

 

Other strategies included Vierordt's method for estimating Dutasteride and Tamsulosin at the same time, as well as Keerthana Diyya's stability-indicating RP-HPLC methodology for analyzing Alfuzosin and Dutasteride together. Furthermore, HPTLC (Kamat et al.) provided a sensitive and reproducible capsule assay, whilst LC-MS/MS (Ramakrishna et al.) allowed for highly sensitive plasma quantification with a limit of quantitation as low as 100pg/mL, making it appropriate for pharmacokinetic research.16-21 Gas chromatography methods (Groman et al.) were developed to manage volatile contaminants in Dutasteride manufacturing and validated according to ICH requirements.22

 

The current study underlines the relevance of validated, precise, and sensitive analytical procedures in ensuring the quality, safety, and efficacy of Dutasteride in pharmaceutical applications, as well as the Greenness evaluation, which is undertaken utilizing the Analytical GREEnness (AGREE) and MoGAPI Assessment tools.

 

MATERIALS AND METHODS:

A LABINDIA T60 dual beam UV-Visble spectrophotometer equipped with Microwave Professionals 2.0 software was used for all spectrophotometric analyses. Measurements were carried out in 1 cm glass cuvettes in the 200-400nm wavelength range. An IBACO Ultra Sonicator was also used for sample preparation. Dutasteride of 99.8% purity (Primus Pharmaceuticals, Ambala) was used as the reference sample, and a commercial capsule formulation (DUTACET, 0.5mg) was obtained for examination. All chemicals and reagents employed were of analytical category, guaranteeing that the process was precise, reproducible, and appropriate for accurate spectrophotometric evaluation of Dutasteride in both bulk and dose forms.

 

 

Preparation of Solvent:

99.5% pure Isopropanol (isopropyl alcohol) was directly utilized in the process.

 

Preparation of Standard Stock Solution (1000μg/ml):

In order to reach a 1000µg/ml solution concentration, 10 mg of carefully measured pure dutasteride was placed in a 10ml volumetric flask, dissolved in isopropanol by hand shaking for two minutes, and then topped off with isopropanol.

 

Preparation of Working Standards (100μg/ml):

1ml of dutasteride was introduced from the aforementioned Standard Stock Solution (1000µg/ml) to a 10ml volumetric flask, and the concentration was adjusted using solvent (Iso-Propanol) to reach 100 µg/ml. The solvent was then used as a blank for a UV spectrophotometer scan between 200 and 400nm.

 

Methodology:

Spectrophotometric technique development and optimization:

In the process, the right wave length is determined by the type of material and how soluble it is. A variety of criteria, including as reagents, reagent concentrations, dilutions, and other temperature conditions, were assessed prior to choosing the analytical conditions in order to develop a spectrophotometric approach that is both acceptable and dependable for the quantitative detection of dutasteride. We used isopropanol as a solvent in our study.

 

Selection of wavelength and determination of λmax:

Use a working standard solution (100µg/ml) as a blank in the UV spectrophotometer, then scan it in spectrum mode between 200 and 400nm. After scanning the resulting solution in a UV spectrophotometer from 200 to 400nm, the λmax of dutasteride was found to be 213 nm.

 

 

Figure 2: Absorption Spectra of Dutasteride

 

Method Validation:

The ICH Guidelines and other literature that focuses on a number of developed and validated analytical procedures was adhered to throughout the procedure.23-36

 

Specificity:

After scanning the blank within the 200–400nm range, it was discovered that there was no interface between the blank and the sample λmax, as depicted in thefigure.

 

 

Figure 3: Blank Peak

                                               

 

Figure 4: Absorption Spectra of Dutasteride

 

Linearity and Range:

The linear regression equation, y=0.016X – 0.0129 for Dutasteride, was found to be linear, with correlation coefficients for Dutasteride is 0.9989, and plotting absorbance values against final concentrations (µg/ml) yielded calibration graphs that were shown to be proportional for concentration ranges of 10–60µg/ml for dutasteride. The values of final concentrations and absorbance shown in the table. It was discovered that the range for Dutasteride was 10–60µg/ml.

 

 

 

Table 1: Linearity Data

Concentration (μg/ml)

Absorbance

0

0

10

0.1556

15

0.2576

20

0.3519

25

0.4143

30

0.4944

35

0.5798

40

0.643

45

0.7327

50

0.8246

55

0.8982

60

0.9673

 

 

Figure 5: Calibration Curve of Dutasteride

 

Precision:

The procedure's repeatability was evaluated by recording the absorbance and scanning a 10µg/ml solution six times. The final result was then used to compute the mean, standard deviation, and percentage RSD. By measuring the absorbance of 10µg/ml on three separate days, inter-day precision (reproducibility) was verified. The findings are displayed in tables for dutasteride. To confirm intraday precision (repeatability), the absorbance of 10µg/ml was measured in the morning, afternoon, and evening on the same day.

 

Table 2: Intraday Precision

Concentration (ug/ml)

Absorbance

Morning

Afternoon

Evening

35

0.5101

0.5865

0.5603

35

0.5246

0.5697

0.5729

35

0.5274

0.5709

0.5694

35

0.5131

0.5542

0.5548

35

0.5252

0.5643

0.5783

0.335

0.5257

0.5779

0.5672

Mean ±SD (n=6)

0.52±0.01

0.57±0.01

0.56±0.01

Standard Deviation

0.01

0.01

0.01

%RSD

1.42

2

1.5

%RSD (n=18)

1.62

 

Table 3: Interday Precision

 

Concentration (µg/ml)

Absorbance

Day-1

Day-2

Day-3

35

0.5578

0.5543

0.5145

35

0.5565

0.5785

0.5143

35

0.5674

0.5651

0.5045

35

0.5741

0.5643

0.5147

35

0.5622

0.5842

0.5194

35

0.5631

0.5674

0.5176

Mean±SD (n=6)

0.56±0.01

0.57±0.01

0.51±0.01

Standard Deviation

0.01

0.01

0.01

% RSD

1.15

1.89

1

% RSD (n=18)

1.35

Note: According to ICH Q2(R1) acceptance limits for %RSD is ≤ 2.0

 

Accuracy:

By creating solutions with varying concentrations (80%, 100%, and 120%), the method's accuracy was assessed. The amount of the marketed formulation DUTACET (Dutasteride 0.5mg) remained constant, while the amount of pure drug was changed to 28μg, 35μg, and 42 μg for Dutasteride 80%, 100%, and 120%, respectively.


 

 

 

 

Table 4: Accuracy Data

Levels

Concentration taken (µg/ml)

Concentration added (µg/ml)

Concentration found (µg/ml)

% Recovery

SD

% RSD of Recovery

80%

35

28

27.4

97.85714

0.04

0.04

35

28

27.39

97.82143

35

28

27.41

97.89286

Mean ±SD (n=3) = 97.86=0.04

100%

35

35

34.56

98.74286

0.03

0.03

35

35

34.55

98.71429

35

35

34.57

98.77143

Mean ±SD (n=3) = 98.74=0.03

120%

35

42

41.5

98.80952

0.04

0.04

35

42

41.48

98.7619

35

42

41.51

98.83333

Mean ±SD (n=3) = 98.80=0.04

 


 

 

Assay and Procedure for Pharmaceutical formulation:

Take twenty tablets, each containing 0.5 mg of dutasteride. placed in a mortar, ground into a fine powder, and blended evenly. Weight corresponding to 10 mg of Dutasteride mixed in an adequate solvent was used to create tablet stock solutions. After twenty minutes of sonication, the solution has been passed through Whatman filter paper (No. 41) and diluted with solvent to make 100 milliliters. The proposed validated approach successfully determined the dosage form's dutasteride concentration. Fill a 10ml volumetric flask with 1ml of a 1000µg/ml solution, then makeup to the volume with 10ml of isopropanol. Measure absorbance of the solution against blank at 213nm.

 

Table 5: Assay data

Tablet Brand name

Drug

Labelled claim (mg)

Amount found (mg)

% of Assay

DUTACET

DUTASTERIDE

0.5

0.496

99.20%

 

Robustness:

By conducting the analysis at distinct wavelengths, the robustness of the approach was assessed.The analysis was conducted at ±2nm from λmax (211nm, 215nm) and with variation in cuvettes The corresponding absorbance values were recorded, and the percentage RSD was used to show the outcome.

 


 

Table 6: Robustness Data

Concentration (µg/ml)

Absorbance at 211nm

Absorbance at 215nm

Absorbance at Cuvette 1

Absorbance at Cuvette 2

35

0.5494

0.5652

0.1581

0.1248

35

0.5698

0.5713

0.1557

0.1251

35

0.5641

0.5623

0.1539

0.1264

35

0.5578

0.5401

0.159

0.1279

35

0.5614

0.5578

0.1577

0.1299

35

0.5566

0.5588

0.1617

0.1255

Mean ±SD (n=6)

0.55=0.01

0.55±0.01

0.15=0.003

0.12=0.002

SD

0.01

0.01

0.003

0.002

%RSD (n=6)

1.25

1.89

1.71

1.55

Note: According to ICH Q2(R1) acceptance limits for %RSD is ≤ 2.0

 


Limit of Detection (LOD) and Limit of Quantification (LOQ):

The limit of detection, or LOD, is the most minimal amount of an analyte in a sample that can be detected under the specific experimental conditions but is not usually quantified. The limit of quantification, or LOQ, is the minimal amount of an analyte in a sample that can be detected under the specified experimental conditions. Dutasteride was found to have a LOD of 0.37 μg/ml and a LOQ of 1.11μg/ml.

 

Table 7: LOD and LOQ Data

LOD

3.3 × SD/SLOPE

3.3 × 0.0018/0.162 = 0.37 μg/ml

LOQ

10 × SD/SLOPE

10 × 0.0018/0.162 = 1.11 μg/ml

 

GREENNESS ASSESSMENT37-39

 

Figure 6: Analytical Greenness report by   a) AGREE metric   b) MoGAPI

The AGREE metric, which is founded on the 12 principles of Green Analytical Chemistry, was used to evaluate the proposed UV-spectroscopic technique for Dutasteride's greenness. Excellent compliance was demonstrated by the technique, which received maximum scores (1.0) for process integration, automation, avoiding derivatization, generating little waste, and getting rid of harmful reagents. Minimal sample size (0.98), low energy usage (0.86), operator safety (0.80), and multi-analyte capacity (0.72) all received moderately high scores. Reagents from renewable sources (0.50) and in-situ measurements (0.66) showed lower compliance. The approach is categorized as environmentally friendly overall, while there is room for improvement.

 

The MoGAPI (Modified Green Analytical Procedure Index) methodology for evaluating the environmental friendliness of analytical techniques is described in the document. It draws attention to characteristics of sample preparation including online or at-line collection, the use of straightforward processes like filtering or decantation, regular storage, and the lack of preservation or transportation. Low health and safety risks (NFPA score 0–1) are prioritized, along with green solvents and minimum reagents (<10mL). Each sample consumes ≤0.1 kWh of equipment, and operator safety is ensured by hermetic sealing. 1–10mL of produced waste doesn't need to be treated. All things considered, MoGAPI encourages sustainable, easy, and environmentally favourable analytical methods.

 

RESULTS AND DISCUSSION:

Dutasteride, an antiandrogenic agent, is employed in the treatment of symptomatic Benign Prostatic Hyperplasia (BPH) in adult males through the inhibition of the enzyme 5-alpha reductase. This compound exhibits distinct analytical properties essential for accurate quantification in pharmaceutical formulations or biological matrices. The maximum absorbance wavelength (λmax) for Dutasteride is observed at 213nm, demonstrating exceptional linearity with a correlation coefficient (r2) of 0.9989, suggestive of a robust association between concentration and absorbance. The molar absorptivity (ε) of Dutasteride is determined to be 6.63 x 102L/mol.cm, with a Sandel’s sensitivity of 0.0625µg/cm3. The slope (b) and intercept (a) for Dutasteride are calculated to be 0.016 and 0.0084, respectively. The regression equation, y =0.016x +0.0084, enables straightforward concentration calculations from absorbance readings. Additionally, Dutasteride exhibits high assay percentage recoveries of 99.2%, affirming the accuracy of the quantification methods. The precision is exhibited by the low intra- and inter-day relative standard deviations (%RSD), which are 1.62% and 1.34%, correspondingly. Dutasteride's limits of quantification (LOQ) and detection (LOD) are set at 1.11µg/ml and 0.37µg/ml, accordingly.

 

Table 8: Optical Characteristics

Parameter

Dutasteride

Linearity (μg/ml)

10-60 μg/ml

Molar absorptivity (L/mol/cm)

6.63 × 102 L/mol/cm

Sandell’s sensitivity (µg/cm˛/0.001 A.U.)

0.0625µg/cm˛/0.001 A.U.

Regression equation

Y=0.016x + 0.0084

Slope (b)

0.016

Intercept (a)

0.0084

Correlation coefficient (r2)

0.999

% Assay

99.2 %

Precision (%RSD)

Intraday-1.62 % and Interday-1.35%

LOD

0.37μg/ml

LOQ

1.11μg/ml

 

AGREE and MoGAPI tools were used to critically assess the developed UV-spectroscopic technique for dutasteride's greenness. Excellent adherence to the fundamentals of Green Analytical Chemistry was validated by the AGREE metric, specifically with regard to avoiding derivatization, waste minimization, process integration, and the removal of toxic chemicals. Its eco-friendly profile was further supported by moderately high ratings for sample size, energy efficiency, and operator safety; nevertheless, areas for development were highlighted by lesser compliance with the use of renewable reagents and in-situ applicability. MoGAPI also placed a strong emphasis on easy sample preparation, safe handling, low energy usage, and minimal reagent consumption. When taken as a whole, the evaluations confirm that the approach is environmentally conscious, effective, and sustainable.

 

CONCLUSION:

The UV-spectroscopic method for dutasteride that was developed is uncomplicated, precise, accurate, and validated in compliance with ICH recommendations. Excellent linearity (r2 = 0.9989), high recovery (99.2%), and low percentage RSD results indicate the approach is reliable and appropriate for routine pharmaceutical analysis. Its dependability is further demonstrated by sensitivity metrics, such as low LOD and LOQ values. Strong adherence to the principles of Green Analytical Chemistry was validated by greenness evaluations using AGREE and MoGAPI, which focused on waste reduction, the removal of hazardous chemicals, and low energy use. The method is deemed environmentally friendly and effective for routine quality control of Dutasteride formulations, notwithstanding the possibility of improvement in the use of renewable reagents and in-situ application.

 

ACKNOWLEDGEMENTS:

The authors would like to thank Dr. Lavu Rathaiahgaru, Chairman of the Vignan group of Institutions for providing all the support to carry out this research work.

 

REFERENCES:

1.      National Center for Biotechnology Information. Dutasteride.https://pubchem.ncbi.nlm.nih.gov/compound/Dutasteride

2.      DrugBank. Dutasteride. https://go.drugbank.com/drugs/DB01126

3.      Cayman Chemical. 15956. https://cdn.caymanchem.com/cdn/insert/15956.pdf

4.      U.S. Food and Drug Administration. Avodart (dutasteride) label.  https://www.accessdata.fda.gov/drugsatfda_docs/label/2020/021319s032lbl.pdf

5.      Drugs.com. Dutasteride. https://www.drugs.com/dutasteride.html

6.      CARE Hospitals. Dutasteride. https://www.carehospitals.com/medicine-detail/dutasteride

7.      Chemical structure of Dutasteride, Chem3D Pro version 7.0.0 software.

8.      Ali, M. S., Alam, M. S., Alam, N., and Siddiqui, M. R. Preparation, characterization and stability study of dutasteride loaded nanoemulsion for treatment of benign prostatic hypertrophy. Iranianjournal of Pharmaceutical Research. 2014; 13(4): 1125–1140.

9.      Wikipedia contributors. Dutasteride.https://en.wikipedia.org/wiki/Dutasteride

10.   Min Mi-Hongv, Park Jin-Hyong et al. Formulation of a film-coated dutasteride tablet bioequivalent to a soft gelatin capsule (Avodart®): Effect of γ-cyclodextrin and solubilizers. Asian Journal of Pharmaceutical Sciences. 2018; 14(3): 313-320. https://doi.org/10.1016/j.ajps.2018.08.007

11.   Garrett D. Pohlman, Emily A. Pohlman, E. David Crawford. Dutasteride: A Review of its Use in the Management of Prostate Disorders. Sage Journals. 2011;3: 171-177. https://doi.org/10.4137/CMT.S1956

12.   Priyadarshani S Bansode, Chetan Singh Chauhan, Preeti Gopaliya et al. Analytical Method Development and Validation of Dutasteride with Tamsulosin in Pharmaceutical Capsule Dosage Form by RPHPLC Method. International Journal of Pharmacy. 2015; 5(2): 493-499.

13.   Patel, D. B., Patel, N. J., Patel, S. K., Prajapati, A. M., and Patel, S. A. RP-HPLC Method for the Estimation of Dutasteride in Tablet Dosage Form. Indian journal of pharmaceutical sciences, 2010; 72(1): 113–116. https://doi.org/10.4103/0250-474X.62247

14.   Kamila M. M, Mondal N, Ghosh L.K. A Validated Spectrophotometric Method for Determination of Dutasteride In Bulk Drug and Pharmaceutical Formulations. International Journal of PharmTech Research. 2010; 2(1): 113-117.

15.   Srinivasarao Y, Kumar TH, Chiranjivi P, Rao KV. Simultaneous Estimation of Solifenacin Succinate and Tamsulosin Hydrochloride in Combined Dosage Form by Using First Order Derivative Spectrophotometric Method. Indian Journal of Pharmaceutical Sciences. 2021; 83(2). DOI: 10.36468/pharmaceutical-sciences.777

16.   Mohammad Kaisarul Islam, Md Ruhul Amin, Moynul Hasan et al. Validated UV Spectrophotometric Method for Estimation of Dutasteride In Tablet Dosage Form. International Journal of Comprehensive Pharmacy. 2011; 1(4): 1-3. https://www.academia.edu/101369144/Pharmacie_Globale_International_Journal_of_Comprehensive_Pharmacy_Validated_Uv_Spectrophotometric_Method_for_Estimation_of_Dutasteride_in_Tablet_Dosage_Form

17.   Abhilasha V.Deshmukh, Mr. Abhay R. Shirode, Dr. Vilasrao J. Kadam. Analytical Method Development and Validation for the Quantitative Estimation of Dutasteride in Its Tablet Dosage Form by RP-HPLC Method. International Journal of Creative Research Thoughts. 2021; 9(6): b120-b133. https://www.researchgate.net/publication/362531207_Analytical_Method_Development_and_Validation_for_the_Quantitative_Estimation_of_Dutasteride_in_Its_Tablet_Dosage_Form_by_RP-HPLC_Method

18.   P. Giriraj, T. Sivakkumar. Simultaneous estimation of dutasteride and tamsulosin hydrochloride in tablet dosage form by vierordt’s method. Arabian Journal of Chemistry. 2017;10(2): S1862- S1867. https://doi.org/10.1016/j.arabjc.2013.07.013.

19.   Keerthana Diyya. Novel Stability Indicating RP-HPLC Method Development and Validation for Simultaneous Estimation of Alfuzosin and Dutasteride in Pharmaceutical Dosage Form. Indian Journal of Pharmaceutical Education and Research. 2020; 54(4): 1144-1152.

20.   S.S. KAMAT et al. Determination of dutasteride from its bulk drug and pharmaceutical preparations by high performance thin layer chromatography. Asian Journal of Chemistry. 2008; 20(7): 5514-5518.

21.   N.V.S Ramakrishna, K.N Vishwottam, S Puran, M Koteshwara, S Manoj, M Santosh. Selective and rapid liquid chromatography–tandem mass spectrometry assay of dutasteride in human plasma. Journal of Chromatography B. 2004; 809(1): 117-124.https://doi.org/10.1016/j.jchromb.2004.06.010

22.   Aleksandra Groman et al. Development and validation of gas chromatography methods for the control of volatile impurities in the pharmaceutical substance dutasteride. Acta Poloniae Pharmaceutica - Drug Research. 2017; 74(5): 1343-1351.

23.   https://database.ich.org/sites/default/files/Q2%28R1%29%20Guideline.pdf

24.   Mounica P Siridevi, Kumar T. Hemant, Rao Y. Srinivasa, Rao K. Varaprasad. Simultaneous Spectrophotometric Estimation of amlodipine besylate and Perindopril Erbumine in tablet Formulation. Research J. Pharm. and Tech. 2019; 12(12): 6101-6106. doi: 10.5958/0974-360X.2019.01060.6

25.   Vidyadhara S, Rao Y. S, Ramu A, Sasidhar R. L, Ramya A. J. Method Development and Validation for the Simultaneous Estimation of Cinitapride and Pantoprazole in Solid Dosage Forms By RP-HPLC. Orient J Chem 2013; 29(3). doi:http://dx.doi.org/10.13005/ojc/290355

26.   Karanam, S.R., Poojitha, N., Vasudha, D. et al. Estimation of Sotagliflozin in Tablet Dosage Form Using UV-Spectrophotometric and RP-HPLC Techniques: A Comparative Study. J Appl Spectrosc. 2025. https://doi.org/10.1007/s10812-025-01953-7

27.   K. Anandakumar, K. Varadharajan, T. Ayyappan, P.Nageswara Rao, K. Sujatha. Estimation of Balsalazide in Bulk and in Formulation by UV-Visible Spectrophotometry. Research J. Pharm. and Tech. 2008; 1(4): 472-474.

28.   R Karthikeyan, B Thangabalan, A ElphinePrabahar, P Vijayaraj Kumar. New Spectrophotometric Methods for the Determination of Imatinib in Bulk Drug and in Pharmaceutical Formulations. Research J. Pharm. and Tech. 2009; 2(3): 578-581.

29.   D B Doshi, P A Bhatt. Development and Validation of UV Spectrophotometric Methods for the Estimation of Pravastatin Sodium in Bulk and Tablet Dosage Form. Research J. Pharm. and Tech. 2010; 3(3): 869-871.

30.   Praveen Kumar, Meenu Chaudhary, S Bhattacharya, Vijay Juyal. Validated Analytical Method Development of Celecoxib in Bulk, Tablet and Rat Plasma by UV-Spectroscopy. Research J. Pharm. and Tech.3 (3): July-Sept. 2010; Page 894-896.

31.   Kumaraswamy G., J.M. Rajendrakumar, J.V.L.N. Sheshagirirao, U. Ashok Kumar, M. Arunadevi. Spectrophotometric Determination of Tenatoprazole in Bulk Drug and Pharmaceutical Dosage Form. Research J. Pharm. and Tech. 2011; 4(4): 574-577.

32.   Prakash S. Sarsambi, Kalyan K., S.A. Raju, L.S. Danki. Development and Validation of Spectrophotometric Methods for the estimation of Gemcitabine in Bulk Drug and its Pharmaceutical Formulations. Research J. Pharm. and Tech. 2011; 4(6): 951-954.

33.   Vijaya Santhi D., Nallagundla H. S. Reddy, Sumalatha N., Jothieswari D. A Novel Estimation of Eprosartan Mesylate in Pure and in Tablet Formulations by Simple UV Method. Research J. Pharm. and Tech. 2011; 4(7): 1069-1072.

34.   34.Pramod Kumar, Babulal Saini, Ravi Dahiya, Jawed Akhtar, Birendra Shrivastav. Development and Validation of UV Spectrophotometric Method for Simultaneous Estimation of Hydrochlorothiazide and Lisinopril in Bulk Drug and Its Formulations. Research J. Pharm. and Tech. 2013; 6(2): 212-215.

35.   Raihan Ahmed, Ramdin S. Supriya, Darade R. Sheetal. Spectrophotometric Method for Simultaneous Estimation of Paracetamol and Cinnarizine in Tablet Dosage Forms. Research J. Pharm. and Tech. 2012; 5(5): 667-671.

36.   B. Siddartha, Sudheer Babu, C. Parthiban, Prathyusha V. Method Development and Method Validation of Tinidazole in Bulk and Pharmaceutical Dosage Form by UV– Spectrophotometric Method. Research J. Pharm. and Tech. 2014; 7(4): 467-469.

37.   Francisco Pena-Pereira,WojciechWojnowski,Marek Tobiszewski. AGREE—Analytical GREEnness Metric Approach and Software. Anal. Chem. 2020, 92, 14, 10076–10082.https://doi.org/10.1021/acs.analchem.0c01887; https://mostwiedzy.pl/AGREE

38.   Mansour FR, Płotka-Wasylka J, Locatelli M. Modified GAPI (MoGAPI) Tool and Software for the Assessment of Method Greenness: Case Studies and Applications. Analytica. 2024; 5(3): 451-457. https://doi.org/10.3390/analytica5030030

39.   Naga Prashant Koppuravuri, Suvarna Yenduri, Varalakshmi H N. Judging the Greenness of Analytical Method using Ecological Foot Prints: A Green Metric Approach. Research Journal Pharmacy and Technology. 2024; 17(12): 6132-6. doi: 10.52711/0974-360X.2024.00930


 

 

Received on 23.08.2025      Revised on 24.11.2025

Accepted on 01.02.2026      Published on 01.09.2026

Available online from September 05, 2026

Research J. Pharmacy and Technology. 2026;19(9):4126-4132.

DOI: 10.52711/0974-360X.2026.00578

© RJPT All right reserved

 

This work is licensed under a Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International License. Creative Commons License.